Recommended Uses:
Use it to waterproof wood, brick, concrete, and metal surfaces and to ensure a continuous air/vapor barrier on the following structures:
Benefits:
Coverages:
Application:
•Apply to clean, dry surface free of oil, grease or residue.
•Use a sample to verify adhesion on the substrate prior to installation. If superior adhesion is required, apply a coat of Grip-Rite™ Primer prior to installing the membrane.
•Use of Grip-Rite primer over surfaces such as OSB, concrete, gypsum or fibreglass structural panels is recommended. Note: Primers take longer time to dry if installed near the prescribed installation temperatures. Plan ahead to allow enough time for primer to dry prior to installing Grip-Rite Window & Door Protector.
•Adhesion of Grip-Rite Window & Door Protector is typically satisfactory over caulks and sealants such as polyurethane, silicones or butyl, provided they are fully cured. Note: It is recommended to test adhesion to surfaces and coatings prior to full application of the membrane.
•Cover Grip-Rite Window & Door Protector with a finishing material immediately after installation.
•Polyurethane may be sprayed over Grip-Rite Window & Door Protector. Note: Membrane should be previously mechanically fastened to the substrate using a termination bar to junctions, window or door frames, endings, and on the perimeter of the building prior to installation.
•Minimum application temperature: 14°F
Window & Door Protector Specifications
Property Standards Window & Door ProtectorThickness — 25 mil
Top face — Trilaminate woven polyethylene
Underface — Clear silicone release film
Tensile strength, MD/XD ASTM D5147 64 / 88 lb./in.
Tensile strength, MD/XD ASTM D412 13.1 Mpa
Ultimate elongation, MD/XD ASTM D5147 40 / 25%
Ultimate elongation, MD/XD ASTM D412 80 / 55%
Static puncture ASTM D5602 90 lbf
Static puncture ASTM E154 168 lbf
Tear resistance, MD/XD ASTM D5601 84 / 90 lbf
Cold temperature flexibility ASTM D5147 -22°F
Lap adhesion ASTM D1876 6.8 lbf/in.
Peel resistance ASTM D903 14.8 lbf/in.
Water absorption ASTM D5147 0.1% max
Water vapor permeance ASTM E96 (Procedure B) 0.016 perm
Air permeability ASTM E283 (75 Pa) 5.8 · 10 ft.³min · ft.²Resistance to sustained wind load ASTM E330 (3000 Pa-10 s) No delamination or variation in the air permeability
Resistance to gust wind load ASTM E330 (100 Pa -1 h) No delamination or variation in the air permeability
-5
lbf= pounds-force/foot Mpa= Megapascal Specifications subject to change without notice.©2024 Company. All Rights Reserved.